500A - 25000A Primary Current Injection Tester Large Current Generator

Product Description

500A - 25000A Primary Current Injection Tester Secondary Injection Test Set

What is it?

The SLQ Series Primary Current Injection Tester is a portable high‑current generator. It draws power from AC220V or AC400V mains and outputs 500A to 25,000A of true power‑frequency current, injected directly into the primary circuit of power equipment (circuit breakers, current transformers, busbars, etc.) to simulate rated load or fault current.

Purpose: Conventional secondary injection tests only check the relay logic, not the complete physical chain (CT → wiring → relay → breaker mechanism). The SLQ uses real primary‑side current to verify CT ratio, secondary loop integrity, protection settings, and breaker trip time – uncovering hidden issues such as CT saturation, hot terminals, or mechanical sticking that secondary tests miss.

Product Highlights

  1. Primary injection, full‑chain verification – no blind spots
    Injecting current directly on the primary side recreates the real fault path. Whether it’s a wrong CT ratio, poor contact in the secondary loop, or an aging trip mechanism, a primary test will reveal it. Much more direct and reliable than secondary injection.

  2. Wide range, one tester for multiple voltage levels
    Output from 500A to 25kA; power supply options AC220V or AC400V. Suitable from low‑voltage distribution rooms to 110kV substations. See Table 1 in the manual – e.g., SLQ-5/1000 (1kA), SLQ-12/4000 (2/4kA dual range), SLQ-150/25kA (25kA).

  3. Customizable high‑accuracy timer – catch every deviation
    Optional 4/5/6‑digit timers with accuracy up to 0.1%RDG+1D, ranges from 0~99.99s to 0~999999s. Measures both millisecond protection trip times and hundreds of seconds of temperature rise tests.

  4. Strict safety & duty cycle protection

    • 100% rated current: max 30s continuous

    • 85% output: max 90s

    • 75% output: max 180s
      Exceeding limits triggers a cooldown recommendation. Also requires reliable grounding before use and prohibits touching hot terminals.

  5. Clear standard configuration – no hidden costs
    Includes control unit, booster (for separated models), user manual, certificate, factory report. High‑current test cables are NOT included – quote separately to avoid misunderstanding.

 System Diagram

Technique Index

1 Power supply: AC220V or AC 400V, 45Hz~65Hz.  The power supply voltage is depends on the power output capacity. Detail information is as table 1.

2 Maximum output current: 500A~25000A. Detail information is as table 1.

3 Impendence voltage: 8%

4 Idle current: 6%

5 Current distortion <5%

6 Current is measured from the secondary of current transformer which is installed in the internal of the current booster. The display mode is customized according to the requirement of customer from the follow list:

1> Analog Current Meter, accuracy class 0.5

2> 4 and 1/2 digitals current meter, accuracy class 0.5

7 work temperature:0~40 C, Humidity <90%

Table 1 Detail configurations for different model current injection tester

Model

Rating capacity

(KVA)

Rating input of Control unit

Rating output of booster

Impedance voltage     

Idle current  

Mode of structure

Booster

Controller

Current

(A)

Voltage

(V)

Current

 (KA)

Voltage

 (V)

SLQ-3/500

3

3

13.6

220

0.5

5

>8

>6

Integral st

SLQ -5/1000

5

5

22.7

220

1

5

>8

>6

Integral/separated

SLQ-8/2000

8

8

36.4

220

2

4

>8

>6

Separated

SLQ-10/2000

10

10

46

220

2

5

>8

>6

Separated

SLQ -12/3000

12

12

55

220

3

4

>8

>6

Separated

SLQ -12/4000

12

12

30

400

2/4

6/3

>8

>6

Separated

SLQ -15/5000

15

15

37.5

400

2.5/5

6/3

>8

>6

Separated

SLQ-24/6000

24

24

60

400

6

4

>8

>6

Separated

SLQ -28/7000

28

28

70

400

7

4

>8

>6

Separated

SLQ-32/8000

32

32

145.5

400

8

4

>8

>6

Separated

SLQ-40/10000

40

40

100

400

10

4

>8

>6

Separated

SLQ -150/25kA

150

150

375

400

25

6

>8

>6

Separated

 

Typical Applications

  • Primary injection trip test for overcurrent relays in substations

  • On‑site CT ratio error & phase displacement calibration

  • Breaker temperature rise & stability test at rated current

  • AC high‑current source for busbar/cable thermal testing

Who should buy it?

  • Power engineering companies, high‑voltage labs

  • Power plant & substation maintenance teams

  • Switchgear and CT manufacturers’ factory test departments

Partner

Product Inquiry

High Current Generator Injector Primary Current Injection Test Set for Circuit Breaker Test

GDPCIT Primary Current Injection Tester for Circuit Breaker Trip Time test

SLQ Series 500A To 10000A Primary Current Injection Test Set High Current Generator