GD-7100IR IEC61010 Battery Internal Resistance Tester Battery Conductance Tester
Product Description
GD-7100IR IEC61010 Battery Internal Resistance Tester Battery Conductance Tester
You Can’t See Internal Battery Damage — But You Can Measure It
Here’s a common situation:
A battery shows full voltage, but it dies quickly under load. The equipment isn’t broken — the battery just has no “strength.”
The real culprit is increased internal resistance.
High internal resistance leads to shorter runtime, more heat, and faster aging of the entire battery bank.
A standard multimeter won’t tell you this.
Many users still rely on voltage checks. But a battery with normal voltage and high resistance is already failing.
What This Tool Actually Solves
GD-7100IR is built specifically to measure internal resistance, voltage, and temperature of rechargeable batteries — lead-acid, lithium, etc.
It’s not another multimeter. It does what multimeters can’t:
No need to disconnect or stop the system
Ignores contact and cable resistance
Gives a clear battery health judgment: PASS / WARNING / FAIL
|Real example:
An active UPS system cannot be shut down. With this tester, you simply clamp the leads, measure online, and get results in about 2 seconds — without interrupting operation.
Why Choose This Over Others?
Common Questions from Real Use
Q: Why do my readings keep fluctuating?
A: On-site noise (from UPS, inverters, etc.) often interferes with 1kHz signals. This tester includes a noise frequency avoidance function. It detects and avoids interference near 1000Hz, giving you stable, repeatable readings.Q: Does cable length affect accuracy?
A: It can. But this device uses an AC 4-terminal method and supports zero adjustment. Even with extension cables, accuracy stays within spec after proper zeroing.
Specs You Can Trust (No Hype)
From the manual — not marketing:
Resistance resolution: 1 μΩ
Voltage resolution: 1 mV
Temperature accuracy: ±1.0℃
These are verifiable, repeatable values — essential for production, maintenance, and acceptance testing.
Specifications
| ARAMETER | VALUE |
|---|---|
| Resistance range | 0.000 mΩ ~ 3.100 Ω (4 ranges, auto/manual) |
| Voltage range | 0.000 V ~ ±122.0 V |
| Temperature range | -10.0℃ ~ 60.0℃ |
| Max input voltage | DC 120V (AC not allowed) |
| Test frequency | 1000Hz ± 5Hz (noise avoidance mode available) |
| Power supply | 3.7V lithium battery, USB charging |
| Auto power-off | ~15 minutes (can be disabled) |
| Weight | 480g (including battery) |
Features
Built for Hands-On Work
3.5" color LCD (320×240)
Direct key access to ranges — no deep menus
Bluetooth connection to phones or tablets for remote viewing
Data You Won’t Lose
10 independent memory banks (A to J)
500 records per bank
USB export to Excel
One-click time sync from PC or phone
Temperature Isn’t an Afterthought
Includes an NTC thermistor input (-10℃ to 60℃).
For lithium or UPS battery banks, temperature rise is often the first sign of trouble.
Where This Is Actually Used
| Application | What It Does |
|---|---|
| Battery production | Sorting by internal resistance, quality check |
| Installation | Verifying new battery bank consistency |
| Routine maintenance | Tracking resistance trends over time |
| Troubleshooting | Finding batteries with normal voltage but high resistance |
| Electrolytic capacitor ESR | Reference only (not a replacement for an LCR meter) |