GDWS micro-moisture dew point analyzer is equipped with a high-performance sensor unit sourced from overseas, along with an anti-contamination gas path filter module. The entire unit features a built-in rechargeable lithium battery and a full set of multi-specification adapters, compatible with SF₆ switchgear chambers. It can also assess the humidity of inert, non-corrosive gases such as nitrogen and dry air. Not only does it output real-time humidity trend curves, but it also helps testers determine whether gas replacement is complete and whether the readings truly approach a steady state.
It is suitable for switchgear manufacturer factory inspections, substation fieldwork, and third-party testing projects.
Availability:
Quantity:
  • GDWS

  • CHONGQING GOLD

In the handover, overhaul, and periodic inspection of GIS and SF₆ circuit breakers, these practical problems are frequently encountered: Dust and oil fumes on-site easily corrode the core sensing unit, shortening probe life; large fluctuations in outdoor temperature and humidity cause readings to oscillate for extended periods, making it difficult to determine when to read valid test data; minor leaks due to poor sealing of gas line joints lead to distorted test results; and data collected on-site requires manual transcription and subsequent manual compilation of test reports, resulting in low efficiency.


4.7-inch Display Smart Gas Moisture Analyzer Quick Response

GDWS Micro-Moisture Dew Point Analyzer, based on the DL/T506-2007 sulfur hexafluoride insulating gas humidity detection standard, is equipped with an original high-performance sensing unit from overseas, coupled with an anti-pollution gas line filter module. The instrument not only outputs the final dew point and volume fraction results but also provides real-time humidity trend curves, helping testers determine whether gas replacement is complete and whether the readings have truly reached a steady state. 

The entire unit has a built-in rechargeable lithium battery and a full set of multi-specification adapters, compatible with SF₆ switch chambers, and can also perform humidity assessments for inert, non-corrosive gases such as nitrogen and dry air.

4.7-inch Display Smart Gas Moisture Analyzer Quick Response side


Product Advantages at a Glance


1.Imported Sensing Unit, Resistant to Field Media Intrusion, Extending Probe Service Life

The core dew point sensing component uses original overseas parts, with an integrated oil, gas, and dust filter module at the front end to block particles and oil contaminants carried out by the SF₆ gas chamber, reducing the risk of field impurities directly corroding the sensor chip. Combined with the instrument's built-in self-calibration logic, it can automatically compensate for probe zero-point drift, reducing the frequency of frequent factory calibrations and maintaining measurement repeatability in variable outdoor environments.


2.Dynamic Trend Curve Visualization, Avoiding Experimental Misjudgments Caused by "Premature Readings"

Unlike conventional equipment that only displays static numbers, the screen synchronously displays a humidity evolution curve over time. Test personnel can intuitively observe the curve convergence state. Only when the curve tends to flatten does it indicate that gas replacement is complete and the system has reached thermal and humidity equilibrium. Only at this point is the collected data valid according to the procedure, avoiding data recording before stability is achieved, which can lead to report distortion.


3.Mature gas circuit system, reducing on-site gas leakage interference. 

The unit is equipped with self-locking quick-connect gas circuit connectors and a complete set of multi-specification transition adapters, compatible with the charging ports of most GIS and SF₆ circuit breakers in China. The flow regulating valve can stably control the sampling conditions within the recommended flow range, reducing measurement deviations caused by abnormal flow rates.


4.Field-friendly local data management, complete closed-loop test archiving. The unit can retain up to 100 timestamped original on-site test records, eliminating the need for manual paper ledgers. Through the RS232 communication interface, it connects to the accompanying PC software for record playback, one-click generation of editable standardized test reports, saving manual data entry and organization, and allowing direct use for project archiving.


5.Complete operational capability without mains power. 

The built-in high-capacity rechargeable lithium battery supports continuous multi-site inspections on a full charge. Testing can be carried out while charging, unaffected by temporary power supply conditions at the substation. The lightweight 3.5kg casing facilitates portability and transport.


6.Open calibration permissions to meet metrological traceability requirements. 

The instrument has local access to zero-point and range parameter calibration. With a standard gas source, parameter values can be corrected on-site, facilitating periodic metrological verification and meeting the metrological traceability management requirements of power equipment testing institutions.



Technical Specifications

Item Specification
Model WAWS3302
Dew‑point Measuring Range -80℃ ~ +20℃
Moisture Volume‑Fraction Range 0‑19999 uL/L
Accuracy ±0.5℃ (-60℃ ~ +20℃)±1.0℃ (-80℃ ~ -60℃)
Resolution Dew‑point:0.1℃;Moisture:1 uL/L
Response Feature 63% reading:5s(-60~+20℃);10s(+20~‑60℃)90% reading:45s(-60~+20℃);240s(+20~‑60℃)
Recommended Sampling Flow 0.6L/min ±20%
Working Gas Pressure Range 0‑1.0 MPa
Operating Ambient Temperature -20℃ ~ +60℃
Ambient Humidity 0‑100%RH(non‑condensing)
Storage Temperature -20℃ ~ +80℃
Battery Charging Duration 4 h
Dimension(L×W×H) 250 × 150 × 300 mm
Net Weight 3.5 kg


Panel and Gas Interface Description

- Gas Inlet: Connects to the gas sampling pipeline of the SF₆ device being tested.

- Gas Outlet: Exhaust gas emission port; toxic/precious gases require a recovery device.

- Flow Adjustment Knob: Controls the sampling gas flow rate, maintaining a standard operating condition of 0.6 L/min.

- RS232 Communication Port: Used for the host computer software to read locally stored records.

- Charging Port: Built-in lithium battery charging interface.

- Status Indicator Lights: Indicate the instrument's self-calibration status.

- 4.7-inch Touchscreen Color Display: Visualizes curves, dew point, micro-moisture volume fraction, system time, and battery level.

4.7-inch Display Smart Gas Moisture Analyzer Quick Response display


Why should we look at the trend curve instead of directly reading the numbers on the screen?

When the sample gas is first connected, ambient air remains inside the pipeline, and gas replacement is not yet complete, causing the readings to drift. A flat curve indicates that the internal gas path has reached equilibrium with the sample gas, and only then will the recorded data meet the test judgment requirements of DL/T506-2007.

What is the purpose of the multi-specification adapter kit?

The thread specifications of the gas charging ports of GIS and SF6 circuit breakers from different manufacturers in China are not standardized. The adapter kit reduces the need to find replacement parts on-site and ensures the joint seal, avoiding lower readings due to minor leaks.

Can the instrument be calibrated without returning to the factory?

The instrument has a local zero-point and range calibration interface. As long as a standard dew point gas source is available, parameter correction can be completed on-site. However, complete metrological verification is still recommended to be performed by a qualified metrology institution.

What gases besides SF₆ can be measured?

Dew point humidity measurement can be performed using non-corrosive inert gases such as nitrogen and dry air, but it cannot be used with gases containing acidic or corrosive components.


Previous: 
Next: 
Product Inquiry

QUICK LINK

PRODUCT LIST

CONTACT US

Phone : +86 15123029885
Add : Building 26, Yubei Intelligent Manufacturing Industrial Park,Liangjiang District, Chongqing, 401120, China.
E-mail : gold05@hy-industry.com
Whatsapp : +8615123029885
Wechat : + 8615123029885
Copyright  Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd. All rights reserved. Site Map
公安备案号 50010802002590