0.02% Accuracy Current Transformer Ratio and Phase Angle Error Test CT PT Analyzer with Laptop Control

Product Description

0.02% Accuracy Current Transformer Ratio and Phase Angle Error Test CT PT Analyzer with Laptop Control

Characteristics of GDVA-405 0.02% Accuracy Current Transformer Ratio and Phase Angle Error Test CT PT Analyzer


1) Comprehensive and accurate testing capability

  • One click automated testing:Automatically measure key parameters such as CT/PT ratio error, angle error, polarity, turns ratio, secondary winding resistance, excitation characteristic curve, saturation point, composite error, etc., meeting international and domestic standards such as IEC60044, IEC61869,IEEE C57.13, GB 1208, etc.

  • High precision measurement: Advanced synchronous sampling and digital signal processing technology are adopted to ensure that the measurement of ratio and angle error reaches 0.05 level or higher accuracy, providing reliable data for energy metering and relay protection.


2) Excellent intelligence and efficiency

  • Powerful built-in power supply: Integrated with a high-power adjustable power supply, all CT/PT tests can be completed without the need for external converters/boosters, greatly simplifying on-site wiring and improving work efficiency.

  • Intuitive and easy-to-use operation: Embedded computer, equipped with a large-sized color touch screen and a graphical guidance interface, making the operation simple and intuitive.

  • Data management expert: With massive storage space, it can save complete test data and waveforms. It can be connected to a laptop via Ethernet for easy data tracing and analysis.


Main Test Items by GDVA-405 IEC61869 CT PT Analyzer:


Tests for current transformer(CT)

Tests for Potential Transformer (PT)

Turn ratio detection

Ratio and phase angle error check

Polarity test

Excitation characteristic test

Secondary winding resistance measurement and secondary burden measurement

5% and 10% error curve measurement

Transient characteristics analysis 

Automatic nameplate inference

Knee point voltage/current

Accuracy Limit Factor (ALF)

Instrument security factor (FS)

Secondary time constant (Ts)

Remanence coefficient (Kr)

Accuracy

Saturation and desaturation inductance

Knee point electromotive force

Limit electromotive force

Area factor

Iron core analysis and core hysteresis loop measurement

PT turns ratio test

Ratio error and phase angle error test

Polarity test

Excitation characteristic test

PT primary winding resistance

Secondary winding resistance

Secondary burden measurement


Specifications:


1) Test standards: IEC60044-1,IEC60044-6,IEC60044-2,IEC60044-5,IEC61869, C57.13

2) Power supply: AC220V±10%, 50/60Hz±10%(Support customize)

3) Voltage output: 0.1~180V (AC)

4) Current output: 0.001~5A(RMS)

5) Power output: 500VA

6) Maximum knee voltage measurement: 60KV

7) Current measurement:

Range: 0~10A (automatically change range in 0.1/0.4/2/10A)

Error: <±0.1%+0.01%FS

8) Voltage measurement:

Range: 0~200V (automatically change range in 1V/10V/70V/200V)

Error: < ±0.1%+0.01%FS

9) Turns ratio measurement: Range:1~35000

1~2000       error<0.05%

2000~5000   error<0.1%

5000~35000  error<0.2%

10) Phase measurement: error: ±2min;    resolution: 0.01min

11) Winding resistance measurement:

Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

Error: < 0.2%RDG+0.02%FS

Maximum resolution: 0.1mΩ

12) Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree

13) CT Secondary burden:

Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

Error: <0.2%RDG+0.02%FS

Maximum resolution: 0.001ohm

14) PT Secondary burden:

Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

Error :<0.2%RDG+0.02%FS

Maximum resolution: 0.1ohm

15) PT ratio measurement: Range: 1~35000

1~10000 error<0.1%

10000~35000 error<0.2%

16) PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%.

17) PT phase angle measurement: maximum error < 3min.

18) Make evaluation for test results according to selected standards.



Contact Us


Contact Person: Christine Gou

Whatsapp/Wechat: +86 15123029885

Mobile: +86 15123029885

E-mail: gold05@hy-industry.com


Product Inquiry

GDVA-405 Automatic CT PT Analyzer with 4KV Voltage Booster for CVT Turns Ratio Test IEC60044-5

GDVA-405 Variable Frequency Automatic CT PT Analyser IEC61869

IEC61869 CT PT Analyzer for Analysis the Excitation Characteristic of Current Transformer and Potential Transformer

GDVA-405 High Efficiency Automatic CT PT Tester for Current Transformer Testing and Assessment

GDVA-405 Automatic CT VT Tester for Multi-tap CT Testing