IEC60044 Current Transformer Tester | CT Analyzer for Current Transformer Calibration

Product Description

IEC60044 Current Transformer Tester | Ct Analyzer for Transformer Calibration

What can it do?


This analyzer can conduct CT excitation parameters & curve tests, ratio & phase error tests, polarity verification, winding resistance, secondary burden measurement, 10% error curve calculation for protection CTs, as well as PT ratio, polarity, secondary burden and winding resistance tests.

It also features nameplate parameter guessing and transient CT analysis, suitable for substations, power plants, and laboratories.

Advantages

  • High accuracy:Ratio error as low as ±0.05% (range 1~2000), phase error ±2min, current measurement error <±0.1%+0.01%FS.

  • Wide range with auto‑ranging:Voltage output 0.1~180V, current output 0.001~5A, power 500VA. Auto‑ranging on all measurements – no manual switching.

  • Low‑frequency excitation technology:Uses frequencies down to 0.25Hz, enabling safe low‑voltage testing of high‑saturation‑voltage CTs (equivalent knee point up to 45kV).

  • Intelligent nameplate guessing:When nameplate data is missing, the analyzer estimates rated primary/secondary current and accuracy class based on measured winding resistance, turns ratio and excitation characteristics.

  • Large memory & reporting:Stores over 1000 test records, generates Word test reports, and exports data to USB drive.

Features

  • Two‑in‑one:Supports full test suites for both current transformers (CT) and voltage transformers (PT).

  • Multi‑standard compliance:Works with IEC60044‑1/2/5/6, C57.13; automatic pass/fail evaluation per selected standard.

  • Auto‑evaluation:Compares measured values against standard limits – failed items highlighted in red.

  • Excitation curve overlay:Compare current curve with a saved curve on the same graph to detect core changes.

  • Built‑in degaussing:Two degaussing cycles are included in the test sequence to ensure repeatability.

  • Safety protections:No direct high‑voltage input; all outputs generated internally. Equipped with grounding terminal and LED status indicator.

Technical Specifications (from manual)

Parameter

Value

Power supply

AC220V±10%, 50/60Hz±10%

Voltage output

0.1~180V (AC)

Current output

0.001~5A (RMS)

Output power

500VA

Max knee voltage measurement

45kV (equivalent)

Current measurement

0~10A, error <±0.1%+0.01%FS, auto‑range

Voltage measurement

0~200V, error <±0.1%+0.01%FS, auto‑range

Turns ratio measurement

Range 1~35000; 1~2000 error<0.05%, 2000~5000<0.1%, 5000~35000<0.2%

Phase measurement

Error ±2min, resolution 0.01min

Winding resistance

0~8kΩ, error <0.2%RDG+0.02%FS, max res. 0.1mΩ

CT secondary burden

0~160Ω, error <0.2%RDG+0.02%FS

PT secondary burden

0~80kΩ, error <0.2%RDG+0.02%FS

PT ratio

1~35000; 1~5000 error<0.2%, 5000~35000<0.5%

Memory capacity

>1000 test groups

Operating temperature

-10℃~50℃, humidity ≤90%

Dimensions

485mm×356mm×183mm

Weight

<15kg

Standard Package Contents

  1. Main unit ×1

  2. 3m shielded cable ×2 (power output / CT secondary)

  3. 10m shielded cable ×1 (CT primary)

  4. Grounding cable ×1

  5. Large test pliers (red & black each 1)

  6. Test gaskets (red×2, black×2), test pins (red×2, black×2), test pliers (red×3, black×9)

  7. Short connection cable (with 6 terminals) ×1

  8. 3A fuse ×3

  9. Power cable ×1

  10. Accessory bag ×1

  11. Production disk (software + manual) ×1

  12. User manual ×2

  13. Inspection report ×1

  14. Certificate of conformity ×1

Product Inquiry

GDVA-405 Automatic CT PT Analyzer with 4KV Voltage Booster for CVT Turns Ratio Test IEC60044-5

0.02% Accuracy Current Transformer Ratio and Phase Angle Error Test CT PT Analyzer with Laptop Control

GDVA-405 Variable Frequency Automatic CT PT Analyser IEC61869

IEC61869 CT PT Analyzer for Analysis the Excitation Characteristic of Current Transformer and Potential Transformer

GDVA-405 High Efficiency Automatic CT PT Tester for Current Transformer Testing and Assessment