1% Accuracy Dissipation Factor Tester Transformer Ipf Insulation Power Factor Tester

Product Description

1% Accuracy Dissipation Factor Tester Transformer Ipf Insulation Power Factor Tester



Why are many devices on the market unable to measure accurately?


Problem 1: Excessive on-site interference

In a substation, the electric field interference generated by surrounding equipment will be directly superimposed on the measurement signal. Ordinary dielectric loss meters do not have effective anti-interference measures, and the data cannot be used.


Problem 2: CVT testing is too complicated

When testing CVTs on many devices, it is necessary to remove the high-voltage leads, which is a large workload and carries high risks.


Problem 3: Only one mode can be tested

Positive connection method, reverse connection method, self-excited connection method, external high voltage... Different test samples require different connection methods. If a device cannot switch flexibly, it will be very passive.



What problem are we solving?


GDGS is a frequency conversion anti-interference tester specialized in measuring dielectric loss (tg δ) and capacitance. It is not a voltage tester, but a tool used to evaluate the degree of insulation aging.



This device can:

1.Is there no power outage online? No, it is used for power outage maintenance scenarios, but it can accurately measure under strong electric field interference

2.When measuring CVT, there is no need to remove the high-voltage lead wire

3.Connect once and measure the dielectric loss and capacitance of C1 and C2 simultaneously

4.Measure LCR parameters of transformers such as inductance, capacitance, and resistance




Advantages and Features

Anti interference technology


  • Built in variable frequency power supply and digital notch filter, supporting:

  • 50Hz, 60Hz single frequency

  • 47.5Hz/52.5Hz, 45Hz/55Hz, 55Hz/65Hz, 57.5Hz/62.5Hz and other frequency conversion combinations

  • Effect: Even with strong on-site interference, stable measurement can still be achieved.

CVT testing


  • Measure the dielectric loss and capacitance of C1 and C2 directly without dismantling the high-voltage leads

  • Supports simultaneous testing of C1 and C2, with two sets of results obtained through a single wiring connection

  • Measurable CVT ratio and voltage angle difference



Positive connection, reverse connection, self excitation, external standard, fully supported


  • GST (Direct Method)/UST (Reverse Method)

  • CVT testing separately/simultaneously/ratio testing

  • GSTg (dielectric loss test between transformer windings)

  • LCR testing (inductance, capacitance, resistance)



Data can be exported


  • Can store 200 sets of test data

  • Support USB drive export

  • Equipped with a thermal printer, the results can be printed directly on site



Technical Parameters


Parameter Value
Operating conditions -15℃ ~ 40℃, RH<80%
Power supply AC 220V ± 10% (generator acceptable)
HV output 0.5kV ~ 10kV, 0.1kV step, max 200mA
Capacity 2000VA
Resolution tgδ: 0.001%, Cx: 0.001pF
Accuracy tgδ: ±(reading × 1.0% + 0.040%)
Cx range 15pF ~ 300nF (varies by test voltage)
CVT ratio range 10 ~ 10000, accuracy ±1%
Storage 200 groups + USB
Host weight 22.75kg


Application Examples

Substation outage maintenance

Bushings, CT, PT, circuit breakers

Transformer insulation assessment

Winding-to-winding and winding-to-ground tgδ

CVT testing

C1, C2, and ratio without removing leads

Insulating oil

Dielectric loss with oil cup

Capacitor banks

Capacitance and tgδ to detect moisture



Partner



Product Inquiry

Fully Automatic Integrated Abnormal Frequency Power Dielectric Loss Analyzer | Transformer Tan Delta Tester

1% Accuracy Automatic Abnormal Frequency Power Dielectric Loss Analyzer Transformer Tan Delta And Power Factor Tester

10kV Transformer Dielectric Loss Tester

GDGS Anti Interference Transformer Capacitance and Dissipation Factor Test Set

GDMZ 10kV Transformer Capacitance Tan Delta Test Kit IPF Insulation Power Factor Test Set