GDJZ Series Oil Immersed Test Transformer AC DC Hipot Tester for Power Transformer Withstand Voltage Testing

GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Cable Withstand Voltage Testing is applied in power system for insulation test, withstand voltage of high voltage equipment like power cable, power transformer, switchgear, etc.
Availability:
Quantity:
  • GDJZ

  • GOLD

  • 9030849000

GDJZ Series

Oil Immersed Test Transformer AC DC Hipot Tester for Power Transformer Withstand Voltage Testing


AC DC hipot tester (9)









Controller

ac dc hipot tester (10)

Oil Type Transformer

AC Hipot tester

Introduction

GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Power Transformer Withstand Voltage Testing is applied in power system for insulation test of high voltage equipment.

The typical application of the HIPOT tester is as follow:

  • Power Transformer AC high voltage withstand test

  • Circuit Breaker AC high voltage withstand test

  • High voltage motors high voltage withstand test

  • Voltage/current transformer high voltage withstand test

  • High voltage power source for calibration of high voltage meter

 


Model Selection Table

  • Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.

  • The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order.

Capacity

KVA

GDJZ-50 Series

GDJZ-100 Series

GDJZ-150 Series

AC

DC

AC

DC

AC

DC

3kVA

50KV

70KV





5kVA

50KV

70KV

100KV

140KV



10kVA

50KV

70KV

100KV

140KV

150kV

210KV

15kVA

50KV

70KV

100KV

140KV

150kV

210KV

20kVA

50KV

70KV

100KV

140KV

150kV

210KV

25kVA

50KV

70KV

100KV

140KV

150kV

210KV

30kVA

50KV

70KV

100KV

140KV

150kV

210KV

50kVA

50KV

70KV

100KV

140KV

150kV

210KV


Notice:

  • If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester;

  • The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table;

  • The weight listed in the table is HV transformer only it does not include the weight of main control box. Please confirm the total weight of the tester with our sales engineer before order;



What's the Difference Between Dry-type, Oil-type, and Gas-filled High Voltage Test Transformers?


AC DC Hipot Tester

Oil Type: The 0-220V/380V voltage is input into the primary winding of the test transformer through an automatic voltage regulator. According to the principle of electromagnetic induction, the power frequency high voltage of the secondary (high voltage) winding is obtained according to the turns ratio of the secondary (high voltage) winding to the primary winding. The oil-immersed test transformer has the characteristics of low cost and cheap price, convenient maintenance, etc., but the disadvantage is that the oil pollution is relatively large and heavy.


Gas-filled Type: SF6 gas has good insulation and arc extinguishing performance. In order to achieve the purpose of insulation, a large amount of SF6 gas was added to the test transformer. According to the insulation and arc extinguishing properties of SF6 gas itself, this type of test transformer has no possibility of reporting discharge even under high voltage conditions, which ensures the accuracy of the test results. However, if the improper use of SF6 gas in the test transformer causes a large amount of volatilization, it will be very troublesome to generate gas in the test transformer, and it generally needs to be sent back to the original manufacturer for processing.


Dry Type: It is a new type of coil epoxy resin vacuum casting and CD core technology. Its basic working principle is: when the input voltage is 200V, when the input voltage is changed according to the needs using the principle of electromagnetic induction, the output high voltage can be continuously adjusted to the rated value by zero voltage. Because it is integrally formed, it cannot be repaired if the internal is damaged , and it is relatively heavy and difficult to move.


AC DC Hipot Tester (2)

AC DC Hipot Tester (1)

Our Partners


Partners



Contact Us


Contact Person: Christine Gou

Whatsapp/Wechat: +86 15123029885

Mobile: +86 15123029885

E-mail: gold05@hy-industry.com



Previous: 
Next: 
Product Inquiry

QUICK LINK

PRODUCT LIST

CONTACT US

Phone : +86 15123029885
Add : Technical Central Building,Eco &Tech Dep Zone, Nan'an District, Chongqing,China
E-mail : gold05@hy-industry.com
Fax : 0086-23-62940030
Whatsapp : +8615123029885
Wechat : + 8615123029885
Copyright  Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd. All rights reserved. Site Map
公安备案号 50010802002590